Moi University Open Access Repository

Assessing the accuracy of a point-of-care analyzer for hyperlipidaemia in western Kenya

Show simple item record

dc.contributor.author Chege, Patrick
dc.date.accessioned 2020-08-01T11:28:11Z
dc.date.available 2020-08-01T11:28:11Z
dc.date.issued 2016
dc.identifier.uri https://onlinelibrary.wiley.com/doi/epdf/10.1111/tmi.12653
dc.identifier.uri http://ir.mu.ac.ke:8080/jspui/handle/123456789/3247
dc.description.abstract objectives The prevalence of hyperlipidaemia, along with other non-communicable diseases, is on the rise in low- and middle-income countries. CardioChek PA is a point-of-care lipid measuring device, which seeks to overcome laboratory-based diagnostic barriers by providing immediate results without dependency on significant laboratory infrastructure. However, it has not been validated in Kenya. In this study, we assess the accuracy of CardioChek PA with respect to the gold standard laboratory-based testing. methods In Webuye, Kenya, two blood samples were collected from 246 subjects to simultaneously measure the lipid levels via both CardioChek PA and the gold standard. All subjects were adults, and geographic stratified sampling methods were applied. Statistical analysis of the device’s accuracy was based on per cent bias parameters, as established by the United States National Institutes of Health (NIH). The NIH recommends that per cent bias be ≤3% for low-density lipoprotein (LDL) cholesterol, ≤5% for high-density lipoprotein (HDL) cholesterol, ≤5% for total cholesterol (TC) and ≤4% for triglycerides (TG). Risk group misclassification rates were also analysed. results The CardioChek PA analyzer was substantially inaccurate for LDL cholesterol (25.9% bias), HDL cholesterol (8.2% bias) and TC (15.9% bias). Moreover, those patients at higher risk of complications from hyperlipidaemia were most likely to be misclassified into a lower risk category. conclusion CardioChek PA is inaccurate and not suitable for our clinical setting. Furthermore, our findings highlight the need to validate new diagnostic tools in the appropriate setting prior to scale up regardless of their potential for novel utility. en_US
dc.language.iso en en_US
dc.publisher Tropical Medicine and International Health en_US
dc.relation.ispartofseries Volume 21;no 3
dc.subject Hyperlipidaemias en_US
dc.subject Cardiovascular diseases en_US
dc.title Assessing the accuracy of a point-of-care analyzer for hyperlipidaemia in western Kenya en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account