Moi University Open Access Repository

Stress - Strain Relations for Steel Fibre Reinforced Concrete Beams in Shear

Show simple item record

dc.contributor.author Nyomboi Timothy
dc.date.accessioned 2018-09-20T11:38:20Z
dc.date.available 2018-09-20T11:38:20Z
dc.date.issued 2001-11
dc.identifier.uri http://ir.mu.ac.ke:8080/xmlui/handle/123456789/1783
dc.description.abstract Fibre reinforced concrete is a relatively application by the construction new construction industry worldwide. Material, with increasing Steel fibres have been found to offer significant increase in the shear strength of plain concrete. Recent research has shown that steel fibre reinforced concrete beams exhibit ultimate shear strengths of ,the same order as those obtained from conventionally reinforced beams (with stirrups) even at a fibre volume of 0.25%. This can be quite advantageous structural members such as ring, lintel, and foundation associated with fabrication and placement when used in beams because of conventional problems steel stirrups, labour and overall costs can be reduced. However, the limiting factor in the use of this material for the purpose discussed above is the lackof design guidelines that can be used in the design for shear in the structural members utilising the material. As a contribution the development of design guidelines, to evolution of the shear stress - strain behaviour in steel fibre reinforced concrete beams was investigated and linear limit and ultimate strengths were determined. Seventeen beams with varying shear span to depth ratio and steel fibre content were tested in three point bending while monitoring the load and the strains at selected points. The beams were reinforced in bending using steel bars with steel fibres as the shear reinforcements. Twelve cylinders with same fibre content as that of the beams were tested in compression while monitoring the load and strains (horizontal and vertical). Theoretical predictions of the non-linear behaviour based on a modification hooke's model in which a strain dependent factor is introduced of and a more advanced model based on the Imam et.al [23] were made and the two models could describe thev experimental results satisfactorily. The prediction of the non-linear behaviour shear stress strain - strain was quite good from the two models particularly 0.5% steel fibre content. It was established of the for the that the linear limit is about 67% of the ultimate shear strength on average. The design application reinforcements of the two proposed models with steel fibres as shear and the classical design method of using shear links was made based on a practical design situation of ring/lintel beam. With the worst condition of loading on the design beam chosen, it was established that the shear stress that arise in lintel / ring are not so high to warrant the use of shear links and could be replaced by steel fibres with use of the proposed models for design. en_US
dc.language.iso en en_US
dc.publisher Moi Univesity en_US
dc.subject Steel en_US
dc.title Stress - Strain Relations for Steel Fibre Reinforced Concrete Beams in Shear en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account